3D reconstruction of the cylindrical assembly of DnaJA2 delta G/F by imposing D5 symmetry
ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
r_long_range_B_refined | 80.982 |
r_mcangle_it | 33.943 |
r_dihedral_angle_2_deg | 26.437 |
r_mcbond_it | 19.202 |
r_dihedral_angle_4_deg | 17.461 |
r_scbond_it | 16.07 |
r_dihedral_angle_3_deg | 14.467 |
r_dihedral_angle_1_deg | 6.241 |
r_angle_refined_deg | 1.484 |
r_chiral_restr | 0.086 |
Sample |
---|
Oligomeric structure of DnaJA2 delta G/F by imposing D5 symmetry |
Specimen Preparation | |
---|---|
Sample Aggregation State | FILAMENT |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 47396 |
Reported Resolution (Å) | 6.9 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | D5 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 30 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1200 |
Maximum Defocus (nm) | 3000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | Preliminary grid screening was performed manually |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | crYOLO | SPHIRE |
IMAGE ACQUISITION | EPU | 1.12 |
CTF CORRECTION | Gctf | |
INITIAL EULER ASSIGNMENT | RELION | 3.0 |
FINAL EULER ASSIGNMENT | RELION | 3.0 |
CLASSIFICATION | RELION | 3.0 |
RECONSTRUCTION | RELION | 3.0 |
MODEL REFINEMENT | REFMAC | 5 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
NONE | 288620 |