The novel asymmetric entry intermediate of a picornavirus captured with nanodiscs
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 1COV |
Sample |
---|
Human coxsackievirus B3 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | GATAN CRYOPLUNGE 3 |
Cryogen Name | ETHANE |
Sample Vitrification Details | Plunged into liquid ethane (GATAN CRYOPLUNGE 3) |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 57203 |
Reported Resolution (Å) | 3.9 |
Resolution Method | FSC 0.143 |
Other Details | (Single particle--Applied symmetry: I) |
Refinement Type | |
Symmetry Type | |
Point Symmetry | I |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (1COV) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | Cross-correlation coefficient | ||||
Overall B Value | 193 | ||||
Fitting Procedure | Real-space refinement | ||||
Details | Initial local fitting was done using Chimera. Phenix was then used for real-space refinement. |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | FEI FALCON II (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) |
Imaging Experiment | 1 |
---|---|
Date of Experiment | 2014-11-21 |
Temperature (Kelvin) | |
Microscope Model | FEI POLARA 300 |
Minimum Defocus (nm) | 1362 |
Maximum Defocus (nm) | 5875 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | SIDE ENTRY, EUCENTRIC |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
Each particle |